MTP2 Framework Test Suite
TEST SUITE OVERVIEW
References ITU-T Q.781
Archive/Project ss7/mtp2_FTS
Version 18653102
Date 30 May 2007
Number of Scenarios 10
Number of Groups 8
Average per Group 1
GROUP/SCENARIO TEST PURPOSE
Link_State_Control_01 Link State Control – Expected signal units/orders
SC_01_01 To check that the No. 7 terminal equipment enters the correct state on power-up.
SC_01_05 To check normal alignment procedure
Link_State_Control_02 Link State Control – Unexpected signal units/orders
SC_02_01 To check that the unexpected signal units/orders are ignored ("Out of service" state)
SC_02_02 To check that the unexpected signal units/orders are ignored ("Not aligned" state)
Transmission_failure_03 Transmission Failure
SC_03_01 Test response to transmission failure – detected by SUERM – when in "Aligned ready" state
SUERM_check_06 SUERM Check
SC_06_04 To check response to a range of time controlled breaks of Tx or Rx
AERM_check_07 AERM Check
SC_07_01 To test the AERM on error rates below the normal threshold
Transmission_and_reception_control_Basic_08 Transmission Control
SC_08_04 To ensure correct performance when an MSU with erroneous FIB is received
Transmission_and_reception_control_PCR_09 Transmission PCR
SC_09_07 To ensure correct performance while RPO is set
Congestion_Control_10 Congestion Control
SC_10_02 To check timer T7 is restarted at the reception of SIB (without expiring of T6)

Variable Default Value Description
ANSI FALSE (null)
MSU_NI_V National_Network_C (null)
MSU_OPC_V 14441 (null)
MSU_DPC_V 14425 (null)
MSU_SLS_V 1 (null)